Service

Air compressor Video Tutorials

Optimise your ABAC compressor with our video tutorials. Learn expert startup procedures and essential maintenance processes. Elevate performance effortlessly. 

Professional car mechanic working in auto repair service using laptop bon car, watching an air compressor maintenance video

Elevate Your Air Compressor with Our Video Guides

Follow our video guides to setup your compressor and perform maintenance tasks. Easy steps explained in our video guides will allow you to extend the life of the product and keep its performance always satysfying. How to carry out a specific operation? How to assembly that piece? Where to find the nearest air compressor service centre?

Direct Driven Compressors


Setup

How to set up an ABAC direct-driven air compressor. Warning: unbox the compressor and make sure it is in perfect condition, checking if it was damaged during the transport. Carry out the operations as showed.


Start

The compressor is fully automatic and is controlled by the pressure switch, which stops it when tank pressure reaches maximum value and restarts it when it falls below a minimum value. Warning: Check that the mains power matches that indicated on the electrical data-plate.


Vessel draining

The compressor generates condensate water which accumulates in the tank. The condensate in the tank must be drained at least once a week, by opening the drain tap under the tank. Warning: Take care if there is compressed air inside the cylinder, and water could flow out with considerable force. Condensate of oil lubricated compressors must not be drained into the sewer or dispersed in the environment as it contains oil. Dispose of it accordingly.


Oil change

The compressor is filled with original oil. We recommend a full change of oil in the pumping element within the first 100 hours of duty. Warning: do not drain used oil into the sewer or dispose of it in the environment.


Air filter cleaning

Every 50 hours of duty we advise you to dismantle the suction filter and clean the filtering element by blowing compressed air on it (fig. 24). You are recommended to replace the filter element at least once if the compressor operates in a clean environment, but more frequently if in a dusty environment.

ABAC OS Super Silent Range


SET UP Abac OS Super Silent air compressors

START Range Abac OS Super Silent range

Abac OS Super Silent - drain condensate

Abac OS Super Silent - clean air filter

Abac OS Super Silent - air filter and chack valve replacement

Belt Driven Compressors


Setup

How to set up an ABAC belt-driven air compressor. Warning: unbox the compressor and make sure it is in perfect condition, checking if it was damaged during the transport. Carry out the operations as showed.


Start

The compressor is fully automatic and is controlled by the pressure switch, which stops it when tank pressure reaches maximum value and restarts it when it falls below a minimum value. Warning: Check that the mains power matches that indicated on the electrical data-plate.


Vessel draining

The compressor generates condensate water which accumulates in the tank. The condensate in the tank must be drained at least once a week, by opening the drain tap under the tank. Warning: Take care if there is compressed air inside the cylinder, and water could flow out with considerable force. Condensate of oil lubricated compressors must not be drained into the sewer or dispersed in the environment as it contains oil. Dispose of it accordingly.


Oil change

The compressor is filled with original oil. We recommend a full change of oil in the pumping element within the first 100 hours of duty. Warning: do not drain used oil into the sewer or dispose of it in the environment.


Air filter cleaning

Every 50 hours of duty we advise you to dismantle the suction filter and clean the filtering element by blowing compressed air on it (fig. 24). You are recommended to replace the filter element at least once if the compressor operates in a clean environment, but more frequently if in a dusty environment.


Belt tensioning and replacement

How to correctly check or change the transmission belt of ABAC lubrified belt driven air compressor. Note: check the tension of the transmission belt. If it bends more than 1cm replace it with a new one.

Professional Air Solutions

ABAC — The Compressed Air Specialist Near You

We are one of the world's leading providers of reliable and innovative compressed air solutions. We make a difference through technology, functionality and design, thanks to our in-house research and development team and extensive experience in the compressed air sector.

ABAC Resources

Buyer's guide

Find our stories, buying guide, product releases and applications insights.

Team of professional carpenters men and women using tablet computers to study and design handicraft furniture in their workshop. technology concept Starting a Successful Small Family Business

ABAC Resources

Maintenance

Find tips and advice to help you keep your air compressor performing at its best.

worker taking note using pen and paper with new young engineer using computer tablet for work faster and more efficiency.

ABAC Resources

Guides

Unlock the potential of your air compressor with expert advice and clever techniques.
Good-looking young man construction worker standing by the table and holding wooden plank while working on laptop

contacts

Contact us

Get help, reach out to our Branches for expert support with air compressors.

Contact_us_man_calling_in industrial_environment

dealers

Find a Local Partner

Find local authorised partners for air compressors. Purchase, install, and service with confidence.

Dealers_partners_world_network_concept